Comparación entre tres muestreadores de material particulado (PM 2.5), en el campus de la UNALM

dc.contributor.advisorPacsi Valdivia, Sergio Artemio
dc.contributor.authorCastelar Ulfe, George Alexis
dc.date.accessioned2019-11-19T20:13:22Z
dc.date.available2019-11-19T20:13:22Z
dc.date.issued2019
dc.descriptionUniversidad Nacional Agraria La Molina. Facultad de Ciencias. Departamento Académico de Ingeniería Ambiental, Física y Meteorología
dc.description.abstractEl presente estudio realizó una comparación entre tres equipos muestreadores de PM2,5 utilizando la metodología de referencia para el muestreo del material particulado atmosférico fino (PM2,5) en el campus de la Universidad Nacional Agraria La Molina (UNALM), distrito de La Molina. Para lograr un adecuado análisis se muestreó dicho contaminante durante un intervalo de cuatro meses (diciembre de 2018 a marzo de 2019), utilizando los equipos: Hivol - 3000, Partisol 2000H y Microvol - 1100, los mismos que se ubicaron en la azotea del Laboratorio de Ingeniería Ambiental; asimismo, se utilizaron datos de la estación meteorológica del Laboratorio de Recursos Hídricos. Por otro lado, se utilizaron datos de concentración de PM2,5 y variables meteorológicas medidos y analizados por SENAMHI y la Embajada de los Estados Unidos. En base a la información proporcionada, se obtuvieron series de tiempo para analizar su comportamiento y tendencia en la zona este de Lima Metropolitana, a nivel horario, diario y mensual para el periodo de muestreo. Los datos de concentración de PM2,5 obtenidos con los distintos equipos de muestreo fueron comparados utilizando el modelo de regresión lineal simple. A partir de las comparaciones realizadas y validadas se obtuvieron las ecuaciones de corrección: PARTISOL=-4,947+0,8195xHIVOL (μg/m3) con un r2=0,764 (válida para el rango de concentración entre 25,43 μg/m3 a 54,95 μg/m3) y PARTISOL=8,853+0,9758xMICROVOL (μg/m3) con un r2=0,735 (válida para el rango de concentración entre 12,52 μg/m3 a 30,87 μg/m3) para el periodo total de muestreo. De la influencia de las variables meteorológicas sobre el PM2,5 se determinó una relación negativa baja respecto a las variables temperatura ambiental, velocidad del viento y radiación solar; por otro lado, se determinó una relación positiva baja con la humedad relativa. Finalmente, se determinó que la adquisición de los equipos Microvol – 1100 y Hivol - 3000 y los filtros empleados para su uso (fibra de cuarzo y fibra de vidrio, respectivamente), representan una menor inversión económica respecto al método de referencia.
dc.description.abstractThe present study made a comparison between three sampling teams of PM2.5 using the reference methodology for the sampling of fine atmospheric particulate material (PM2.5) on the campus of the National Agrarian University La Molina (UNALM), district of La Molina. To achieve an adequate analysis, this contaminant was sampled over a four-month interval (December 2018 to March 2019), using the equipment: Hivol - 3000, Partisol 2000H and Microvol - 1100, the same that were located on the roof of the Laboratory of Environmental Engineering; likewise, data from the meteorological station of the Water Resources Laboratory were used. On the other hand, PM2,5 concentration data and meteorological variables measured and analyzed by SENAMHI and the United States Embassy were used. Based on the information provided, time series were obtained to analyze their behavior and tendency in the eastern part of Metropolitan Lima, at the hourly, daily and monthly level for the sampling period. The PM2,5 concentration data obtained with the different sampling equipment were compared using the simple linear regression model. From the comparisons made and validated, the correction equations were obtained: PARTISOL=-4,947+0,8195xHIVOL (μg/m3) with a r2 = 0.764 (valid for the concentration range between 25,43 μg/m3 to 54,95 μg/m3) and PARTISOL=8,853+0,9758xMICROVOL (μg/m3) with a r2 = 0,735 (valid for the concentration range between 12,52 μg/m3 to 30,87 μg/m3) for the total period of sampling. From the influence of the meteorological variables on the PM2,5 a low negative relationship was determined with respect to the variables environmental temperature, wind speed and solar radiation; on the other hand, a low positive relationship with relative humidity was determined. Finally, it was determined that the acquisition of the Microvol - 1100 and Hivol - 3000 equipment and the filters used for its use (quartz fiber and glass fiber, respectively), represent a lower economic investment with respect to the reference method.
dc.description.uriTesis
dc.formatapplication/pdf
dc.identifier.otherT01.C378-T BAN UNALM
dc.identifier.urihttps://hdl.handle.net/20.500.12996/4186
dc.language.isospa
dc.publisherUniversidad Nacional Agraria La Molina
dc.publisher.countryPE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectDeposición atmosférica
dc.subjectPolución del aire
dc.subjectEquipo
dc.subjectMuestreo
dc.subjectDistribución espacial
dc.subjectGravimetría
dc.subjectMedición
dc.subjectEvaluación
dc.subjectAnálisis cuantitativo
dc.subjectAnálisis de costos
dc.subjectUniversidades
dc.subjectPerú
dc.subjectMuestreadores de material particulado
dc.subjectUniversidad Nacional Agraria La Molina
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#1.05.08
dc.titleComparación entre tres muestreadores de material particulado (PM 2.5), en el campus de la UNALM
dc.typeinfo:eu-repo/semantics/bachelorThesis
dc.type.versioninfo:eu-repo/semantics/publishedVersion
renati.advisor.dni06301457
renati.advisor.orcidhttps://orcid.org/0000-0003-4262-0593
renati.author.dni70083089
renati.discipline521066
renati.jurorUnsihuay Tovar, Franklin Delio
renati.jurorAramayo Bazzetti, Armando Javier
renati.jurorBaldeón Quispe, Wilfredo Celestino
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttps://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineIngeniería Ambiental
thesis.degree.grantorUniversidad Nacional Agraria La Molina. Facultad de Ciencias
thesis.degree.nameIngeniero Ambiental

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
castelar-ulfe-george-alexis.pdf
Size:
10.04 MB
Format:
Adobe Portable Document Format
Description:
Texto completo

License bundle

Now showing 1 - 1 of 1
Name:
license.txt
Size:
1.64 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections