Tanque Baffled para el tratamiento primario de agua residual doméstica

dc.contributor.advisorMiglio Toledo, Rosa María
dc.contributor.authorOyarce Alvarez, Luciana Patricia
dc.date.accessioned2022-02-21T19:50:37Z
dc.date.available2022-02-21T19:50:37Z
dc.date.issued2021
dc.descriptionUniversidad Nacional Agraria La Molina. Facultad de Ingeniería Agrícola. Departamento Académico de Ordenamiento Territorial y Construcción
dc.description.abstractEl tanque baffled es un reactor anaerobio diseñado para ser empleado en zonas peri urbanas o rurales, aunque existe evidencia de que se ha utilizado para tratar aguas residuales domésticas pertenecientes a un municipio en África. En la presente investigación se evaluó la operación y eficiencia de un tanque baffled ubicado en la Planta Piloto de Tratamiento de Aguas Residuales de la Universidad Nacional Agraria la Molina; el tanque baffled consta de 3 cámaras o compartimentos y ha sido diseñado para tratar 6 m3 /d de agua residual doméstica. Se monitoreó la eficiencia del tratamiento durante un período de 8 semanas, con muestreos semanales; considerando 2 puntos de muestreo: ingreso y salida del agua residual. Se midieron parámetros físico-químico y microbiológicos, alcanzándose eficiencias de remoción de 70% para DBO5, 78% para DQO, 73% para turbiedad, 92% para SST, 99% para sólidos sedimentables y 2 unidades logarítmicas para coliformes totales. Hidráulicamente el tanque operó con un caudal promedio de 2.82 m3 /d, con un tiempo de retención real de 13 horas, aproximadamente. Las eficiencias alcanzadas muestran un desempeño muy prometedor para que el sistema sea instalado en poblaciones rurales y pequeños municipios a nivel nacional, donde mayoritariamente se emplean tanques sépticos con eficiencia de remoción de DBO5 entre 30 y 40% y tanquesimhoff, con eficiencia de remoción en DQO entre 25 y 50%. (Tilley et.al., 2014)
dc.description.abstractThe baffled tank is an anaerobic reactor designed to be used in peri-urban or rural areas, although there is evidence that it has been used to treat domestic wastewater belonging to a municipality in Africa. In this research, the operation and efficiency of a baffled tank located in the Pilot Plant for Wastewater Treatment of the “Universidad Nacional Agraria la Molina” was evaluated; the baffled tank consists of 3 chambers or compartments and has been designed to treat 6 m3/d of domestic wastewater. Treatment efficiency was monitored over a period of 8 weeks, with weekly samplings; considering 2 sampling points: entry and exit of wastewater. Physical-chemical and microbiological parameters were measured, reaching removal efficiencies of 70% for BOD5, 78% for COD, 73% for turbidity, 92% for TSS, 99% for settleable solids and 2 logarithmic units for total coliforms. Hydraulically, the tank operated with an average flow of 2.82 m3/d, with a real retention time of approximately 13 hours. The efficiencies achieved show a very promising performance for the system to be installed in rural populations and small municipalities nationwide, where mostly septic tanks are used with BOD5 removal efficiency between 30 and 40% and imhoff tanks, with removal efficiency in COD between 25 and 50%. (Tilley et.al., 2014)
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.12996/5229
dc.language.isospa
dc.publisherUniversidad Nacional Agraria La Molina
dc.publisher.countryPE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectAguas residuales
dc.subjectTratamiento de aguas residuales
dc.subjectTratamiento primario
dc.subjectTanques
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.07.01
dc.titleTanque Baffled para el tratamiento primario de agua residual doméstica
dc.typeinfo:eu-repo/semantics/bachelorThesis
dc.type.versioninfo:eu-repo/semantics/publishedVersion
renati.advisor.dni07548510
renati.advisor.orcidhttps://orcid.org/0000-0002-2214-2187
renati.author.dni46825844
renati.discipline811096
renati.jurorCalle Maraví, José Luis
renati.jurorBravo Aguilar, Carlos Alberto
renati.jurorVela Cardich, Rosemary
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttps://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineIngeniería Agrícola
thesis.degree.grantorUniversidad Nacional Agraria La Molina. Facultad de Ingeniería Agrícola
thesis.degree.nameIngeniero Agrícola

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
oyarce-alvarez-luciana-patricia.pdf
Size:
4.1 MB
Format:
Adobe Portable Document Format
Description:
Texto completo

License bundle

Now showing 1 - 1 of 1
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections