Mostrar el registro sencillo del ítem

dc.contributor.advisorEnciso Gutiérrez, Antonio Celestino
dc.contributor.advisorPaz Zagaceta, Fernando
dc.contributor.authorPalma Moscoso, Jorge Luis
dc.date.accessioned2020-03-10T19:32:42Z
dc.date.available2020-03-10T19:32:42Z
dc.date.issued2019
dc.identifier.urihttps://hdl.handle.net/20.500.12996/4354
dc.descriptionUniversidad Nacional Agraria La Molina. Facultad de Ingeniería Agrícola. Departamento Académico de Recursos Hídricoses_PE
dc.description.abstractEl presente trabajo de investigación consistió en emplear un equipo de fertirriego no convencional (bomba fumigadora) basado en pistones para evaluar los coeficientes de uniformidad de riego y la uniformidad de concentración en las muestras de agua que emitieron los goteros de tres módulos de riego de alta frecuencia (subunidad), instalando para este fin una parcela demostrativa con tres subunidades de riego dentro del campo experimental de la FIA en la UNALM (Lima). Cada sub unidad utilizó emisores de riego diferente: en la subunidad N°1 tubería integrada de alto espesor con goteros autocompensantes Azud Premier pc 2.3 l/h, subunidad N°2 goteros de botón no compensantes Naandanjain J- Turbo keyplus 2 l/h y en la subunidad N°3 tubería integrada de bajo espesor con goteros no compensantes Azud Sprint 1.6 l/h; en cada una de las sub unidades se instaló una válvula de acople para adicionar fertilizante mediante una bomba fumigadora marca Lucatti. El promedio de resultados del coeficiente de uniformidad de las subunidades sin uso del equipo de inyección fue: Sub unidad con goteros Azud Premier pc 93.45%, Subunidad con goteros Naandanjain J.P 88.87%, Sub unidad con goteros Azud Sprint. 83.48%; el promedio de los resultados del coeficiente de uniformidad de las subunidades usando el equipo de inyección fue:Sub unidad con goteros Azud Premier pc 94.22%, Subunidad con goteros Naandanjain J.P 89.57%, Sub unidad con goteros Azud Sprint. 85.1%, con respecto a la concentración de fertilizante se determinó el PH y la C.E que emitieron los goteros en análisis obteniendo una uniformidad para el PH Y C.E para Sub unidad con goteros Azud Premier de 95.71% y 95.37%, respectivamente; en la Subunidad con goteros Naandanjain fue de 94.04% y 92.77% respectivamente y por último en la Subunidad con goteros Azud Sprint fue un promedio de 93.23% y 92.89% respectivamentees_PE
dc.description.abstractThe present research work consisted in evaluating the uniformity coefficient and the uniformity of fertilizer concentration of three subunits of drip irrigation, using in the analysis an unconventional fertilizer injection equipment (fumigant pump) carried out in a plot installed for this purpose within the experimental field of the FIA in the UNALM (Lima). Each sub unit used different irrigation emitters: in sub-unit No. 1 integrated high-thickness pipe with self-compensating drippers (Azud Premier pc 2.3 l / h), subunit No. 2 non-compensating button drippers (Naandanjain J- Turbo keyplus 2 l / h) and in sub-unit No. 3 integrated low-thickness pipe with non-compensating drippers (Azud Sprint 1.6 l / h). A fumigating pump was coupled as a fertilizer injection equipment in the subunits. The average results of the uniformity coefficient of the subunits without use of the injection equipment were: Sub unit with Azud Premier PC droppers 93.45%, Subunit with Naandanjain droppers J.P 88.87%, Sub unit with Azud Sprint droppers. 83.48%; the average of the results of the uniformity coefficient of the subunits using the injection equipment was: Sub unit with droppers Azud Premier pc 94.22%, Subunit with drippers Naandanjain J.P 89.57%, Sub unit with Azud Sprint droppers. 85.1%, with respect to the concentration of fertilizer was determined the pH and C.E that emitted the drippers in analysis obtaining a uniformity for the PH and C.E for Sub unit with Azud Premier drippers of 95.71% and 95.37%, respectively; in the subunit with Naandanjain drippers it was 94.04% and 92.77% respectively and finally in the subunit with Azud Sprint drippers it was an average of 93.23% and 92.89% respectivelyen_US
dc.formatapplication/pdfen_US
dc.language.isospaes_PE
dc.publisherUniversidad Nacional Agraria La Molinaes_PE
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectRecursos hídricoses_PE
dc.titleDeterminación de la concentración de fertilizantes y el coeficiente de uniformidad en tres tipos de goteros usando un inyector de pistoneses_PE
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
thesis.degree.disciplineIngeniería Agrícolaes_PE
thesis.degree.grantorUniversidad Nacional Agraria La Molina. Facultad de Ingeniería Agrícolaes_PE
thesis.degree.nameIngeniero Agrícolaes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#4.05.00es_PE
renati.author.dni45228493es_PE
dc.publisher.countryPEes_PE
dc.type.versioninfo:eu-repo/semantics/publishedVersionen_US
renati.advisor.orcidhttps://orcid.org/0000-0001-6834-7121es_PE
renati.advisor.dni07575481es_PE
renati.advisor.dni08170284es_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline811096es_PE
renati.jurorAguilar Giraldo, Guillermo Clemente
renati.jurorAlata Rey, Josué Eliezer
renati.jurorArapa Quispe, José Bernardino


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess