Mostrar el registro sencillo del ítem

dc.contributor.advisorMiglio Toledo, Rosa María
dc.contributor.authorHerrera Manrique, Alexander Jacinto
dc.date.accessioned2021-01-13T00:52:47Z
dc.date.available2021-01-13T00:52:47Z
dc.date.issued2020
dc.identifier.urihttps://hdl.handle.net/20.500.12996/4547
dc.description.abstractEl incremento poblacional y crecimiento vertical de las ciudades, condicionan la necesidad de implementar viviendas con tanques de almacenamiento de agua potable. Los objetivos de esta investigación fueron determinar las alteraciones bacteriológicas y la eficacia de dos métodos de desinfección para tanques domiciliarios. Esta investigación se desarrolló en un sector de Villa María del Triunfo en la ciudad de Lima, donde el agua es administrada por la empresa SEDAPAL. Los tratamientos fueron cinco tanques con limpieza y desinfección; cinco sin limpieza y desinfección, y tres viviendas sin tanques de almacenamiento, constituyeron los tratamientos que proporcionaron las muestras de agua, tomadas con frecuencia de 14 días, durante 13 meses (marzo 2015 - marzo 2016). Aplicando los métodos adecuados se hizo el reconteo de bacterias heterótrofas, coliformes totales y la determinación del cloro residual libre. La prueba estadística T de Student para muestras independientes, se usó para validar los resultados. Se concluye que el promedio de bacterias heterótrofas es significativamente mayor en las muestras de tanques sin limpieza y desinfección. De la misma forma 68 por ciento de estas muestras presentaron concentraciones de cloro residual libre por debajo de 0,5 ppm. Se confirmó que presencia de tanques de almacenamiento de agua en las viviendas, alteran la calidad de la misma. Se determinó que después de 189 días, la concentración de bacterias heterótrofas supera los valores que específica la normativa, esto implica que el mantenimiento en los tanques debe hacerse cada seis meses. Las muestras tomadas en las viviendas sin tanques de almacenamiento avalan la buena calidad del agua, entregada por SEDAPAL a los usuarios, cumpliendo así con lo estipulado en la normativa vigente.es_PE
dc.description.abstractThe increase in population and vertical growth of the cities, conditions the need to implement houses with potable water storage tanks. The objectives of this research was to determine the bacteriological alterations and the effectiveness of two methods of disinfection for residential water tanks. These investigation was developed in a sector of Villa Maria del Triunfo in the city of Lima, where the water is administrated by SEDAPAL. The treatments were: Five tanks cleaned and disinfected; five without cleaning and disinfection, and water from the pipeline of three houses without storage tanks. These treatments provided the water samples, taken with a frequency of 14 days, during 13 months (March 2015 - March 2016). By applying the appropriate methods, according to the standards of water quality; heterotrophic bacteria, total coliforms and the determination of free residual chlorine were counted. The statistical T Student test for independent samples was used to validate the results. It is concluded that the average of heterotrophic bacteria is significantly higher in the tanks without cleaning and disinfection. In the same way, 68 percent of these samples showed concentrations of free residual chlorine below 0.5 ppm, which is below the parameters stablished by the standards. It was confirmed that the presence of water storage tanks in the houses, changes the quality of the water. It was determined also that after 189 days, the concentration of heterotrophic bacteria exceeds the values specified in the local regulations, this means that the maintenance in the water tanks must be done every six months. The samples taken in the pipelines of houses without storage tanks guarantees the good quality of the water delivered by SEDAPAL to the users, thus accomplishing what is stipulated in the current local regulations.en_US
dc.formatapplication/pdfen_US
dc.language.isospaes_PE
dc.publisherUniversidad Nacional Agraria La Molinaes_PE
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectAguaes_PE
dc.subjectTanqueses_PE
dc.subjectMonitoreoes_PE
dc.subjectContaminación del aguaes_PE
dc.subjectPolución del aguaes_PE
dc.subjectCalidad del aguaes_PE
dc.subjectMuestreoes_PE
dc.subjectEvaluaciónes_PE
dc.titleAlteraciones de la calidad bacteriológica del agua almacenada en tanques de conexiones domiciliarias, abastecidos con agua potable de Sedapales_PE
dc.typeinfo:eu-repo/semantics/masterThesisen_US
thesis.degree.disciplineCiencias Ambientaleses_PE
thesis.degree.grantorUniversidad Nacional Agraria La Molina. Escuela de Posgradoes_PE
thesis.degree.nameMagister Scientiae - Ciencias Ambientaleses_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.07.01es_PE
renati.author.dni28308400es_PE
dc.publisher.countryPEes_PE
dc.type.versioninfo:eu-repo/semantics/publishedVersionen_US
renati.advisor.orcidhttps://orcid.org/0000-0002-2214-2187es_PE
renati.advisor.dni07548510es_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/nivel#maestroes_PE
renati.discipline521087es_PE
renati.jurorQuinteros Carlos, Zulema
renati.jurorVela Cardich, Rosemary
renati.jurorMeza Contreras, Víctor


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess