dc.description.abstractEl presente estudio realizó una comparación entre tres equipos muestreadores de PM2,5 utilizando la metodología de referencia para el muestreo del material particulado atmosférico fino (PM2,5) en el campus de la Universidad Nacional Agraria La Molina (UNALM), distrito de La Molina. Para lograr un adecuado análisis se muestreó dicho contaminante durante un intervalo de cuatro meses (diciembre de 2018 a marzo de 2019), utilizando los equipos: Hivol - 3000, Partisol 2000H y Microvol - 1100, los mismos que se ubicaron en la azotea del Laboratorio de Ingeniería Ambiental; asimismo, se utilizaron datos de la estación meteorológica del Laboratorio de Recursos Hídricos. Por otro lado, se utilizaron datos de concentración de PM2,5 y variables meteorológicas medidos y analizados por SENAMHI y la Embajada de los Estados Unidos. En base a la información proporcionada, se obtuvieron series de tiempo para analizar su comportamiento y tendencia en la zona este de Lima Metropolitana, a nivel horario, diario y mensual para el periodo de muestreo. Los datos de concentración de PM2,5 obtenidos con los distintos equipos de muestreo fueron comparados utilizando el modelo de regresión lineal simple. A partir de las comparaciones realizadas y validadas se obtuvieron las ecuaciones de corrección: PARTISOL=-4,947+0,8195xHIVOL (μg/m3) con un r2=0,764 (válida para el rango de concentración entre 25,43 μg/m3 a 54,95 μg/m3) y PARTISOL=8,853+0,9758xMICROVOL (μg/m3) con un r2=0,735 (válida para el rango de concentración entre 12,52 μg/m3 a 30,87 μg/m3) para el periodo total de muestreo. De la influencia de las variables meteorológicas sobre el PM2,5 se determinó una relación negativa baja respecto a las variables temperatura ambiental, velocidad del viento y radiación solar; por otro lado, se determinó una relación positiva baja con la humedad relativa. Finalmente, se determinó que la adquisición de los equipos Microvol – 1100 y Hivol - 3000 y los filtros empleados para su uso (fibra de cuarzo y fibra de vidrio, respectivamente), representan una menor inversión económica respecto al método de referencia.es_PE
dc.description.abstractThe present study made a comparison between three sampling teams of PM2.5 using the reference methodology for the sampling of fine atmospheric particulate material (PM2.5) on the campus of the National Agrarian University La Molina (UNALM), district of La Molina. To achieve an adequate analysis, this contaminant was sampled over a four-month interval (December 2018 to March 2019), using the equipment: Hivol - 3000, Partisol 2000H and Microvol - 1100, the same that were located on the roof of the Laboratory of Environmental Engineering; likewise, data from the meteorological station of the Water Resources Laboratory were used. On the other hand, PM2,5 concentration data and meteorological variables measured and analyzed by SENAMHI and the United States Embassy were used. Based on the information provided, time series were obtained to analyze their behavior and tendency in the eastern part of Metropolitan Lima, at the hourly, daily and monthly level for the sampling period. The PM2,5 concentration data obtained with the different sampling equipment were compared using the simple linear regression model. From the comparisons made and validated, the correction equations were obtained: PARTISOL=-4,947+0,8195xHIVOL (μg/m3) with a r2 = 0.764 (valid for the concentration range between 25,43 μg/m3 to 54,95 μg/m3) and PARTISOL=8,853+0,9758xMICROVOL (μg/m3) with a r2 = 0,735 (valid for the concentration range between 12,52 μg/m3 to 30,87 μg/m3) for the total period of sampling. From the influence of the meteorological variables on the PM2,5 a low negative relationship was determined with respect to the variables environmental temperature, wind speed and solar radiation; on the other hand, a low positive relationship with relative humidity was determined. Finally, it was determined that the acquisition of the Microvol - 1100 and Hivol - 3000 equipment and the filters used for its use (quartz fiber and glass fiber, respectively), represent a lower economic investment with respect to the reference method.en_US
dc.formatapplication/pdfen_US
dc.language.isospaes_PE
dc.publisherUniversidad Nacional Agraria La Molinaes_PE
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectDeposición atmosféricaes_PE
dc.subjectPolución del airees_PE
dc.subjectEquipoes_PE
dc.subjectMuestreoes_PE
dc.subjectDistribución espaciales_PE
dc.subjectGravimetríaes_PE
dc.subjectMediciónes_PE
dc.subjectEvaluaciónes_PE
dc.subjectAnálisis cuantitativoes_PE
dc.subjectAnálisis de costoses_PE
dc.subjectUniversidadeses_PE
dc.subjectPerúes_PE
dc.subjectMuestreadores de material particuladoes_PE
dc.subjectUniversidad Nacional Agraria La Molinaes_PE
dc.titleComparación entre tres muestreadores de material particulado (PM 2.5), en el campus de la UNALMes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
thesis.degree.disciplineIngeniería Ambiental, Física y Meteorologíaes_PE
thesis.degree.grantorUniversidad Nacional Agraria La Molina. Facultad de Cienciases_PE
thesis.degree.nameIngeniero Ambientales_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#1.05.08es_PE
renati.author.dni70083089
dc.publisher.countryPEes_PE
dc.type.versioninfo:eu-repo/semantics/publishedVersionen_US
renati.advisor.orcidhttps://orcid.org/0000-0003-4262-0593es_PE
renati.advisor.dni06301457es_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesis
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline521066es_PE
renati.jurorUnsihuay Tovar, Franklin Delio
renati.jurorAramayo Bazzetti, Armando Javier
renati.jurorBaldeón Quispe, Wilfredo Celestino


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess