Show simple item record

dc.contributor.advisorQuipuzco Ushñahua, Lawrence Enrique
dc.contributor.authorCondori Pantoja, Antonio Miguel
dc.date.accessioned2018-11-05T16:35:35Z
dc.date.available2018-11-05T16:35:35Z
dc.date.issued2018
dc.identifier.otherT01.C6557-T BAN UNALM
dc.identifier.urihttps://hdl.handle.net/20.500.12996/3627
dc.descriptionUniversidad Nacional Agraria La Molina. Facultad de Ciencias. Departamento Académico de Ingeniería Ambiental, Física y Meteorologíaes_PE
dc.description.abstractCon el objetivo de evaluar la tratabilidad de los efluentes generados de un laboratorio metalúrgico por medio de la electrocoagulación, se diseñó un electrocoagulador a escala de dimensiones de 40.8 cm de largo, 10.6 cm de ancho y 14 cm de alto con una capacidad de 6.168 L. Se utilizaron 20 placas para cada ensayo de hierro y aluminio y estas placas se conectaron en paralelo con una configuración bipolar a una fuente de corriente continua. Las mejores condiciones para la remoción de los metales (plomo, cadmio y cromo) fueron: material de los electrodos de aluminio, una distancia entre placas de 1 cm y un tiempo de retención de 60 minutos. Tomando estas condiciones como el escenario más eficiente, el proceso de electrocoagulación redujo el plomo en 94.47 por ciento, el cadmio en 46.11 por ciento y el cromo en 49.46 por ciento. Para plomo y el cadmio a pesar de la remoción obtenida, no estuvieron dentro de los Valores Máximos Admisibles, a diferencia del cromo que previo al tratamiento ya se encontraba dentro de lo permitido. Además durante el proceso se generó sulfuro de hidrógeno gaseoso en bajas concentraciones, el cual se percibió como un olor a huevo podrido durante el proceso.es_PE
dc.description.abstractIn order to evaluate the treatability of the effluents generated from a metallurgical laboratory by means of electrocoagulation, an electrocoagulator was designed to scale with dimensions of 40.8 cm long, 10.6 cm wide and 14 cm high with a capacity of 6,168 L 20 plates were used for each test of iron and aluminum and these plates were connected in parallel with a bipolar configuration to a direct current source. The best conditions for the removal of metals (lead, cadmium and chromium) were: material of the aluminum electrodes, a distance between plates of 1 cm and a retention time of 60 minutes. Taking these conditions as the most efficient scenario, the electrocoagulation process reduced lead by 94.47 percent, cadmium by 46.11 percent and chromium by 49.46 percent. For lead and cadmium, despite the removal obtained, they were not within the Maximum Admissible Values, unlike the chromium that prior to the treatment was already within the allowed. In addition, during the process hydrogen sulfide gas was generated in low concentrations, which was perceived as a rotten egg odor during the process.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfen_US
dc.language.isospaes_PE
dc.publisherUniversidad Nacional Agraria La Molinaes_PE
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceUniversidad Nacional Agraria La Molinaes_PE
dc.sourceRepositorio institucional - UNALMes_PE
dc.subjectMetales pesadoses_PE
dc.subjectEfluenteses_PE
dc.subjectContaminanteses_PE
dc.subjectCoagulaciónes_PE
dc.subjectConductividad eléctricaes_PE
dc.subjectDiseñoes_PE
dc.subjectEvaluaciónes_PE
dc.subjectPerúes_PE
dc.subjectTratabilidad de metales pesadoses_PE
dc.subjectLaboratorio metalúrgicoes_PE
dc.subjectElectrocoagulaciónes_PE
dc.titleEvaluación de la tratabilidad del efluente generado por un laboratorio metalúrgico aplicando la electrocoagulaciónes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
thesis.degree.disciplineIngeniería Ambiental, Física y Meteorologíaes_PE
thesis.degree.grantorUniversidad Nacional Agraria La Molina. Facultad de Cienciases_PE
thesis.degree.nameIngeniero Ambientales_PE
thesis.degree.levelTítulo Profesionales_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.07.01es_PE


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess